26 parts
Power Switch
–
–
| Part Number | Package | R_ON (mΩ) | VIN (V) | ILIM (A) | IOUT (A) | Channel | Features |
|---|---|---|---|---|---|---|---|
| PSW509H05D-S5 | SOT23-5L | 67 | 2.7 – 5.5 | - | 0.5 | 1 | Under Voltage Lockout No Reverse Current when Power Off Deglitched Open-Drain Over-Current Flag Output OC Output Shutdown Pull-low Resistor Output Reverse Protection when Power ON |
| PSW509L05D-S5 | SOT23-5L | 67 | 2.7 – 5.5 | - | 0.5 | 1 | Under Voltage Lockout No Reverse Current when Power Off Deglitched Open-Drain Over-Current Flag Output OC Output Shutdown Pull-low Resistor Output Reverse Protection when Power ON |
| PSW509H05N-S5 | SOT23-5L | 67 | 2.7 – 5.5 | - | 0.5 | 1 | Under Voltage Lockout No Reverse Current when Power Off Deglitched Open-Drain Over-Current Flag Output OC Output Shutdown Pull-low Resistor Output Reverse Protection when Power ON |
| PSW509L05N-S5 | SOT23-5L | 67 | 2.7 – 5.5 | - | 0.5 | 1 | Under Voltage Lockout No Reverse Current when Power Off Deglitched Open-Drain Over-Current Flag Output OC Output Shutdown Pull-low Resistor Output Reverse Protection when Power ON |
| PSW509H10D-S5 | SOT23-5L | 67 | 2.7 – 5.5 | 1.1 – 1.5 | 1 | 1 | Under Voltage Lockout No Reverse Current when Power Off Deglitched Open-Drain Over-Current Flag Output OC Output Shutdown Pull-low Resistor Output Reverse Protection when Power ON |
| PSW509L10D-S5 | SOT23-5L | 67 | 2.7 – 5.5 | 1.1 – 1.5 | 1 | 1 | Under Voltage Lockout No Reverse Current when Power Off Deglitched Open-Drain Over-Current Flag Output OC Output Shutdown Pull-low Resistor Output Reverse Protection when Power ON |
| PSW509H10N-S5 | SOT23-5L | 67 | 2.7 – 5.5 | 1.1 – 1.5 | 1 | 1 | Under Voltage Lockout No Reverse Current when Power Off Deglitched Open-Drain Over-Current Flag Output OC Output Shutdown Pull-low Resistor Output Reverse Protection when Power ON |
| PSW509L10N-S5 | SOT23-5L | 67 | 2.7 – 5.5 | 1.1 – 1.5 | 1 | 1 | Under Voltage Lockout No Reverse Current when Power Off Deglitched Open-Drain Over-Current Flag Output OC Output Shutdown Pull-low Resistor Output Reverse Protection when Power ON |
| PSW509H20D-S5 | SOT23-5L | 67 | 2.7 – 5.5 | 2.2 – 2.8 | 2.1 | 1 | Under Voltage Lockout No Reverse Current when Power Off Deglitched Open-Drain Over-Current Flag Output OC Output Shutdown Pull-low Resistor Output Reverse Protection when Power ON |
| PSW509L20D-S5 | SOT23-5L | 67 | 2.7 – 5.5 | 2.2 – 2.8 | 2.1 | 1 | Under Voltage Lockout No Reverse Current when Power Off Deglitched Open-Drain Over-Current Flag Output OC Output Shutdown Pull-low Resistor Output Reverse Protection when Power ON |
| PSW509H20N-S5 | SOT23-5L | 67 | 2.7 – 5.5 | 2.2 – 2.8 | 2.1 | 1 | Under Voltage Lockout No Reverse Current when Power Off Deglitched Open-Drain Over-Current Flag Output OC Output Shutdown Pull-low Resistor Output Reverse Protection when Power ON |
| PSW509L20N-S5 | SOT23-5L | 67 | 2.7 – 5.5 | 2.2 – 2.8 | 2.1 | 1 | Under Voltage Lockout No Reverse Current when Power Off Deglitched Open-Drain Over-Current Flag Output OC Output Shutdown Pull-low Resistor Output Reverse Protection when Power ON |
| PSW509H25D-S5 | SOT23-5L | 67 | 2.7 – 5.5 | 2.7 – 3.7 | 2.6 | 1 | Under Voltage Lockout No Reverse Current when Power Off Deglitched Open-Drain Over-Current Flag Output OC Output Shutdown Pull-low Resistor Output Reverse Protection when Power ON |
| PSW509L25D-S5 | SOT23-5L | 67 | 2.7 – 5.5 | 2.7 – 3.7 | 2.6 | 1 | Under Voltage Lockout No Reverse Current when Power Off Deglitched Open-Drain Over-Current Flag Output OC Output Shutdown Pull-low Resistor Output Reverse Protection when Power ON |
| PSW509H25N-S5 | SOT23-5L | 67 | 2.7 – 5.5 | 2.7 – 3.7 | 2.6 | 1 | Under Voltage Lockout No Reverse Current when Power Off Deglitched Open-Drain Over-Current Flag Output OC Output Shutdown Pull-low Resistor Output Reverse Protection when Power ON |
| PSW509L25N-S5 | SOT23-5L | 67 | 2.7 – 5.5 | 2.7 – 3.7 | 2.6 | 1 | Under Voltage Lockout No Reverse Current when Power Off Deglitched Open-Drain Over-Current Flag Output OC Output Shutdown Pull-low Resistor Output Reverse Protection when Power ON |
| PSW517AH-TS | TSOT23-6L | 60 | 2.7 – 5.5 | 0.5 – 2.7 (adj.) | 3 | 1 | Current Limits with Foldback Under voltage Lockout No Reverse Current when Power Off Deglitched Open-Drain Over-Current Flag Output (FLAG) Output Reverse Current Protection |
| PSW517AL-TS | TSOT23-6L | 60 | 2.7 – 5.5 | 0.5 – 2.7 (adj.) | 3 | 1 | Current Limits with Foldback Under voltage Lockout No Reverse Current when Power Off Deglitched Open-Drain Over-Current Flag Output (FLAG) Output Reverse Current Protection |
| PSW517AH-S6 | SOT23-6L | 60 | 2.7 – 5.5 | 0.5 – 2.7 (adj.) | 3 | 1 | Current Limits with Foldback Under voltage Lockout No Reverse Current when Power Off Deglitched Open-Drain Over-Current Flag Output (FLAG) Output Reverse Current Protection |
| PSW517AL-S6 | SOT23-6L | 60 | 2.7 – 5.5 | 0.5 – 2.7 (adj.) | 3 | 1 | Current Limits with Foldback Under voltage Lockout No Reverse Current when Power Off Deglitched Open-Drain Over-Current Flag Output (FLAG) Output Reverse Current Protection |
| PSW517AH-TV | TDFN2020-6L | 60 | 2.7 – 5.5 | 0.5 – 2.7 (adj.) | 3 | 1 | Current Limits with Foldback Under voltage Lockout No Reverse Current when Power Off Deglitched Open-Drain Over-Current Flag Output (FLAG) Output Reverse Current Protection |
| PSW517AL-TV | TDFN2020-6L | 60 | 2.7 – 5.5 | 0.5 – 2.7 (adj.) | 3 | 1 | Current Limits with Foldback Under voltage Lockout No Reverse Current when Power Off Deglitched Open-Drain Over-Current Flag Output (FLAG) Output Reverse Current Protection |
| PSW516A1-T8 | TSOT23-8L | 50 | 4 – 20 | 3.4 – 4 | 3.7 | 1 | UVLO, Adj OVLO (OVTH pin), Active-High EN, Fast OC with FLAG, reverse-V protect |
| PSW516A2-T8 | TSOT23-8L | 50 | 4 – 20 | 3.4 – 4 | 3.7 | 1 | UVLO, Adj OVLO (OVTH pin), Active-Low EN, Fast OC with FLAG, reverse-V protect |
| PSW516A3-T8 | TSOT23-8L | 50 | 4 – 20 | 3.4 – 4 | 3.7 | 1 | UVLO, Adj OVLO (OVTH pin), Active-High EN, deglitched OC FLAG, reverse-V protect |
| PSW910Z-N25 | TQFN2×2.5-12L | 55 | 2.8 – 22 | 1 – 5 (adj.) | 4.5 | 2:1 | Seamless Switchover Between Two Inputs (2.8V–22V) Programmable Current Limit 1A–5A Programmable OV Supervisor (OV1, OV2) Programmable Priority Supervisor (PR1, CP2) True Reverse-Current Blocking 500ns Fast-Trip Short-Circuit Protection Programmable Soft-Start (SS) Channel-Status Output (ST) Thermal Shutdown with Auto-Retry |